CJFZW - READY GEL, 586601
- MSDS: CJFZW
- Manufacturer: BECKMAN INSTRUMENTS INC
- Product Name: READY GEL, 586601
- National Stock Number: 6850-00N091051
Product Identification
Product ID:READY GEL, 586601
MSDS Date:11/21/1989
FSC:6850
NIIN:00N091051
MSDS Number: CJFZW
Responsible Party
FULLERTON, CA 92634
US
Emergency Phone: 714-773-8061
Info Phone: 714-773-8061
Cage: 05721
Contractor
Telephone: 714-773-8061
Cage: 05721
Ingredients
PSEUDOCUMENE; (WITH P-XYLENE CAS# 1330-20-7 59%)
CAS: 95-63-6
RTECS: DC3325000
ACGIH TLV: 25 PPM APPROX.
NON-IONIC EMULSIFIER + FLUORS
XYLENE; (P-XYLENE WITH PSEUDOCUMENE CAS#95-63-6 59%)
CAS: 1330-20-7
RTECS: ZE2100000
ACGIH TLV: 434 MG/M3;100 PPM
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MAY CAUSE DIFFICULTY WITH BREATHING.
MAY BE A RESPIRATORY IRRITANT OR SKIN IRRITANT. CONSULT A PHYSICIAN
IF SYMPTOMS PERSIST. THRESHOLD LIMIT VALUE: APPROX. 25 PM.
First Aid
First Aid:EYE CONTACT: IRRIGATE WITH WATER FOR AT LEAST 15 MINUTES, GET
MEDICAL ATTENTION. SKIN CONTACT: WASH WITH SOAP AND WATER, REMOVE
CONTAMINATED CLOTHES, USE APPROVED LOTION OR CREAM TO REPLACE SKIN
OILS. INHALATION: GET VICTIM TO FRESH AIR. INGESTION: DO NOT
INDUCE VOMITING. CONSULT A PHYSICIAN.
Fire Fighting
Flash Point Method:CC
Flash Point:>40.C, 104.F
40-42
Lower Limits:1.1%
Upper Limits:7.0%
Extinguishing Media:DRY CHEMICAL, FOAM, CO*2, WATER FOG.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT . A WATER STREAM CAN SCATTER FLAMES.
Unusual Fire/Explosion Hazard:VAPOR HEAVIER THAN AIR, MAY FLOW TO
DISTANT IGNITION SOURCES.
Accidental Release
Spill Release Procedures:NOTIFY SAFETY PERSONNEL, REMOVE ALL IGNITION
SOURCES, PROVIDE ADEQUATE VENTILATION. USE VERMICULITE OR SAND TO
ABSORB SPILL AND PLACE IN COVERED METAL CONTAINER.
Handling
Handling and Storage Precautions:STORE IN A COOL, WELL VENTILATED AREA
AWAY FROM SOURCES OF HEAT OR IGNITION.
Other Precautions:AVOID REPEATED OR PROLONGED BREATHING OF VAPOR. DO
NOT INGEST!
Exposure Controls
Respiratory Protection:NIOSH APPROVED ORGANIC VAPOR CANISTER
RESPIRATORS.
Ventilation:LOCAL EXHAUST: EFFICIENT; MECHANICAL: REQUIRED TO CONTROL
TO TLV OR BELOW.
Protective Gloves:BUNA N RUBBER.
Eye Protection:ANSI APPROVED CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA . PLASTIC APRON.
Supplemental Safety and Health
Chemical Properties
Boiling Pt:=150.C, 302.F
B.P. Text:APPROX.
Vapor Pres:6.25 @ 20C
Vapor Density:4 (AIR =1)
Spec Gravity:0.94 (H*2O = 1)
Evaporation Rate & Reference:0.6 (BUAC = 1)
Solubility in Water:DISPERSES
Appearance and Odor:COLORLESS LIQUID, AROMATIC ODOR
Percent Volatiles by Volume:59
Stability
Stability Indicator/Materials to Avoid:YES
OXIDIZING AGENTS.
Stability Condition to Avoid:STABLE, KEEP AWAY FROM HEAT SOURCES,
IGNITION SOURCES, AND OXIDIZING AGENTS.
Hazardous Decomposition Products:OXIDES OF CARBON.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:SCRAP LIQUID MAY BE ATOMIZED INTO AN APPROVED
INCINERATOR OR DISPOSED OF VIA A LICENSED DISPOSAL COMPANY. THIS
MATERIAL MAY BE A HAZARDOUS WASTE AND MUST BE MANAGED IN ACCORDANCE
WITH APLICABLE LOCAL, STATE, AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.